Semi-gloss indoor paint for premises with constant humidity
Colour: White
Consumption: Consumption on the absorbing surface of 7…8 m²/L, consumption of non-absorbent surface of 9…10 m²/L. For painting 1 m² s required approximately 140…160 ml of paint i, depending on the surface.
Drying time: At the temperature of +20 °C and the relative humidity of 80%, the surface is ready for the application of another coat in 1–1,5 hours. The surface is fully dry in 12 hours.
Volume / weight: 0,9L – 2,7L – 9L
Semi-gloss acrylate water-borne paint for wet indoor areas with high performance and hygienic requirements.
Gloss:
Wash resistance:
Painting walls and ceilings in rooms with high performance and hygienic requirements as well as humid and wet rooms where the condensation of moisture on surfaces is likely (bathrooms, kitchens, laundry rooms, swimming pools, entrance halls, corridors, production facilities, public catering facilities, hospitals, schools, garages, metro facilities, underground facilities, etc.). Not suitable for painting floors, doors and furniture.
Surfaces previously painted with latex, alky or oil-base paints or new surfaces made of concrete, aerated concrete, gypsum board; brick; surfaces finished with putty or plastered and surfaces covered with glass fibre wallpaper or other rolled finishing materials. For interior use.
Previously unpainted surfaces: Clean the surface, removing dirt and dust. If necessary, apply a suitable putty from the FILLER line to the surface. Sand the filled surface to make it even and remove sanding dust. Prime filled, porous or unevenly porous surfaces with Aquastop or Tiefgrund moisture barrier (follow the product instructions for use). Prime the surfaces with water-borne priming paint Flat to even out the surface absorption capacity, increase the durability of the painted surface and decrease the consumption of the top coat paint.
Previously painted surfaces: the painted surface must be cleaned from loose and peeling material, grease, dust and other impurities. If mould removal is necessary, use Biotol E or Biotol Spray (follow the product instructions for use). To clean the surfaces that are very dirty or have soot, water, nicotine or grease stains use EasyClean. Then prime with the isolating paint Objekt. Before painting durable old alkyd surfaces, sand them until they are matt and remove sanding dust thoroughly. Use a putty from the FILLER line to fill cracks, holes and uneven areas. Sand the filled surface to make it even and remove sanding dust. Prime filled surfaces with Aquastop or Tiefgrund moisture barrier to reduce porosity. Prime the surfaces with water-borne priming paint Flat to decrease the consumption of the top coat paint and improve coverage.
Stir the paint thoroughly before application. Mixing tinted paint in one container is recommended. Apply 2 coats with a roller or spray gun at the temperature between +10 °C and +25 °C and relative air humidity below 80%. When using a spray gun or for the application of the first coat, dilute the paint with water in the amount of 5% until it reaches working viscosity. Apply undiluted paint for the finishing coat. Avoid application in drafty places and at high air temperature (over +25 °C). When painting, make sure to keep a wet edge. If you must work in unfavorable conditions (drafts, heating devices, high temperature, low humidity), we recommend adding the TIME+ drying time extender (up to 3% of the paint volume).
The coating reaches its peak wash resistance in about 3…4 weeks; in the meantime, treat the surface with care until its hardness and wash resistance have reached their peak levels. If necessary, the surface can be lightly wiped with a soft sponge or cloth approximately 48 hours after paint application.
Professional detergents and disinfectants used in medical facilities (wards, corridors, rooms for medical procedures, operating rooms), childcare facilities and food industry companies can be used to wash the painted surface. Do not use organic solvents, abrasive detergents, stiff brushes or rough sponges. Excessive rubbing may make the surface glossy. Wipe the surface dry after wet cleaning. Use Biotol E and Biotol Spray to remove mould.
Roller, airless spray gun. For application with an airless spray gun, use the nozzle diameter 0.021-0.027”
Wash with soap and water after completing work.
Store and transport in a tightly sealed container at the temperature between +5…30 °С. Protect from exposure to freezing and direct sunlight.
The information concerning the product is based on the results of laboratory tests and practical use of the product depending on the location and conditions of its use. As the manufacturer, we guarantee the quality of the product and provide the best recommendations for its appropriate application. As the manufacturer, we cannot control the conditions and circumstances of product transportation, storage and application and numerous other factors that affect its use. Thus, we shall not bear responsibility for the damage caused by ignoring the instructions for use or transportation, by noncompliance with storage conditions and timeframes or by inappropriate application of the product. The manufacturer reserves the right to alter product information at their discretion without prior notice.
Kulu arvutatakse 1 kihile